Garage Doors & Openers
Sales/Service/Installation
Showroom/Parts Dept.
1851 Lincoln Hwy. East
Lancaster, Pa. 17602
(717)394-4724
|
|
Hoist Model DH![]() Logic 3.0 Technology (L3)
Added Value
Reliability & Programming Simplicity
Mechanical Reversing Contactor Circuit (M): (115V, 208/230V, 460V, 575V, 24V NEC Class 2 Circuit with 40VA transformer) Industrial linear contactor provides significantly longer control runs than conventional contactors.
Standard Features
Motor: Continuous-duty high-starting torque motor with instant reverse and overload protection. Available in 1/3 and 1/2; single- or three-phase. Removable without affecting limit switch settings.
Door Lock Sensor: Adjustable door lock sensor can detect if the door lock is engaged and will stop the operator, eliminating jamming and damage to the door or operator.
Drive Reduction: First-stage heavy-duty 5L V-belt; second and third stages #48 chain; #50 drive chain.
Emergency Disconnect: Easy emergency manual operation using an electrically interlocked floor level disconnect and hoist mechanism.
Wiring Type: D1, C2 and B2 wiring types are all available. D1 wiring is standard and is pre-wired to accept a photoelectric control, sensing edge, radio controls and most types of access control devices. Failsafe wiring can be selected with the addition of a CPS-L, CPS-LN4 or failsafe edge and CPS3 card.
External Radio Control Terminal: Quick, convenient connections for retrofitting or adding radio controls on logic or mechanical operators.
Bearings: Industrial ball bearings on a 1" output shaft; heavy-duty oil-filled iron bearings on reduction shafts.
Friction Clutch: Adjustable, helps protect against major damage to door and operator should the door meet an obstruction.
Construction: NEMA 1 type electrical box, heavy-duty 11-gauge steel frame with durable powdercoat finish, all reduction sprockets drilled and pinned to shafts.
Push Button Station: 2-button station for open/close functions is standard with D or D1 wiring. 3-button station is standard with B2 or C2 wiring.
Positive Locking Mechanical Brake System: Self-locking mechanical reduction system that functions as a holding brake.
Control Accessories
CPS® Commercial Protector System®: (recommended) A “non-contact” photo safety sensor designed to sense an obstruction and signal the door operator to reverse to open.
Sensing Edge: (recommended) Designed to sense an obstruction and signal door operator to stop or reverse as desired. An electric or pneumatic sensing device can be added to bottom edge of door.
2-Position Keylock (flush mount): Ideal for use with the DJ operator. Provides open/close operation with spring to center (Model 02-109).
Available Plug-in Options for Logic 3.0 (L3)
Auxiliary Contact: Used to operate security, warning, heating or other 5V to 240V devices. Features both normally open and closed contacts that actuate in conjunction with limit switches.
Warning Signal: Red/green light module provides safety warning prior to close (when using timer-to-close feature). Also supports audio warning devices and includes down mid-stop feature.
CPS3 Option: Enables the addition of a second set of photo-eyes or 2- or 4-wire, self-monitoring edge.
|
||